Operator’s Guide Appendix I
002-5572 RJS, Minneapolis, MN
51
Figure I-2 (Code 3 of 9 Passing)
Inspector D4000L
Revision A.06
Cont. Scan Analysis
Code 3of9
Acceptable
*708101000021075
3*
#Decodes 011/012
%Decodes 091%
Ratio: 2.8 P
D/bility .62 A
-100% Tol. +100%
--RAR---++++++++
Continuous Mode
Enabled
During the time the
trigger was de-
pressed, 12 reads
were attempted and
11 of those were good
for a total of 91% of
the scans
Komentarze do niniejszej Instrukcji