Operator’s Guide Appendix B
002-5572 RJS, Minneapolis, MN
33
Appendix B (Symbology Analysis)
Symbology Analysis Parameters
Table B-1 shows error messages that will be displayed
for each parameter type checked by the RJS Inspector
D4000.
Table B-1 (Parameter/Error Message)
Parameter Data Analysis Message
Ratio Warning Ratio
Ratio 1.8 < or > 3.4 Rejected Ratio
Inter-Character Gap (ICG) Bad ICG
Invalid Data Character Invalid format
Too Few Characters Invalid format
I 2 of 5 Case code not 14 or 18
characters
Invalid format
Code 128 GS1 Case code not
14 or 18 characters or not all
numeric characters
Invalid format
Mod Check Digits Bad Mod. Check
PCS Rejected PCS
Bar Width Deviation Edge of
Range (Wide)
Warning Wide
Bar Width Deviation Edge of
Range (Narrow)
Warning Narrow
Bar Width Deviation Out of
Range (Wide)
Rejected Wide
Bar Width Deviation Out of
Range (Narrow)
Rejected Narrow
Addendum Parity (UPC/EAN) Invalid Format
ISO/ANSI Decodability (if
enabled)
Warn D/bility (DCD, in initial
Pass/Fail screen)
Object in Quiet Zone Defects F, 50% or greater
Quiet Zone Too Small Warning QZ/SS
<Fnc1> with Standard C128 Format Warning
No <Fnc1> with GS1 Selected Warn Missing F1
Przeglądanie stron 40