Inspector D4000™ Laser SP Operator’s Guide
RJS, Minneapolis, MN 002-5572
A symbol is “Acceptable” until any calculated bar width
deviation exceeds 100% of the tolerance for the
symbology decoded; for example:
Bar Width - Acceptable
-100% Tol. +100%
------RRARR+++++
Bar Width - Warning
-100% Tol. +100%
--------++RRRARR
Bar Width - Rejected
-100% Tol. +100%
--------+++++++R
“A” is out of tolerance and off the screen.
Note:
Could also be on negative side (See Table 8-A for vis-
ual display of deviations)