Operators Guide Appendix G
002-5564 RJS, Minneapolis, MN
49
Table G-2 (Parameters Checked for Each Symbology)
Symbology Ratio ICG Data
Character
Mod
Check
Tolerance
AIAG B-1 2.2-3.2 .5X-8X STD CODE 39 N/A ((12R-8)/81)X
AIAG B-3
B-4 B-5
2.8-3.2
.5X-8X
$/+%
Not Allowed
N/A
((12R-8)/81)X
LOGMARS 2.2-3.0 .5X-8X STD CODE 39 N/A ((12R-8)/81)X
CODE 3 OF 9 2.2-3.0 .5X-8X STD CODE 39 N/A ((12R-8)/81)X
3 OF 9 W/43 2.2-3.0 .5X-8X STD CODE 39
4 CHARS Min
MOD 43 ((12R-8)/81)X
HIBC 3 OF 9 2.2-3.0 .5X-8X STD CODE 39
Min 2 CHARS
1ST. = "+"
MOD 43 ((12R-8)/81)X
INTERLVD 2 OF 5
2.2-3.0 N/A N/A N/A ((18R-1)/80)X
CASE CODE 2.3-2.9 N/A 3 Data Chars
Min.
MOD 10 ((18R-1)/80)X
CODE 128 N/A N/A N/A MOD 103 .35X
CASE
CODE 128
N/A N/A 16 Data Char.
Format Check
Mod 10
Mod 102
.35X
UPC/EAN N/A N/A N/A MOD 10 See Note 1
(bottom of
pg.)
CODABAR
VARIANT
2.2-3.0 .5X-8X STD
CODABAR
N/A ((5R-8)/20)X
CODE 93 N/A N/A STD CODE 93 C&K .35X
Note 1:
X = X dimension
Tolerance is expressed as a fraction of the X dimension
R = Ratio in the calculations
UPC/EAN tolerances:
80 - 89% = .14X
90 - 115% = .30X
116 - 150% = .34X
151 - 200% = .38X