Inspector D4000™ Auto Optic Operator’s Guide Manual P/N 002-7856 Revision: B July 2013 THIS MANUAL APPLIES ONLY TO FIRMWARE A.06 OR LA
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 1.4 CE: This equipment generates, uses, and can radiate radio frequen
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 3 1.8 Installing Batteries Slide opens the plastic cover on the back of
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 1.9 Technical Support Please read the manual and try to understand it,
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 5 2.0 Warranty 2.1 General Warranty Warranty information: +1 (763) 746-
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 2.3 Service during the Warranty Period If your RJS Inspector D4000 sho
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 7 3.0 Introduction 3.1 RJS Inspector D4000 Description and Features The
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 3.3 Temperature Specs Do not operate or store your unit or components
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 9 4.0 The RJS Inspector D4000 Auto Optic Note: Calibration plaqu
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 5.0 Main Menu Selections 5.1 Calibration Power On When the unit is pow
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 11 Verifying that Unit is Calibrated Selecting CALIB sets up the mode t
Inspector D4000™ Auto Optic
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 hold auto-optic scanner head still until you hear a “chirp” sound. Pl
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 13 5.2 Scan After finishing calibration press Select and Enter at the s
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 5.3 Setup Select Setup (from the Main Menu) to view various system par
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 15 The next selection is Passing Grade: Passing Grade B Selec
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Three choices are available in Auto Print Mode: 1. Analysis Only: (Fo
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 17 The next selection is Decode I 2 of 5: Decode I 2of 5 as Std I 2
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 The next selection allows you to select a range of UPC/EAN symbol magn
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 19 5.4 Storage Storage will display as either Storage Inactive or Stor
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 When Storage is active, press Select to move the cursor to the % sign.
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 21 6.0 PCS Analysis PCS scanning (overview) This section is an overview
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN Copyrights The copyrights in this manual are owned by R
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 7.0 Scanning Symbols Scanning Techniques Lay the symbol to be scann
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 23 8.0 Pass/Fail Analysis Screen After the symbol is scanned the Pass/
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Below is a sample of scans remaining in multiple scan mode if the last
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 25 On the previous tables, all ISO/ANSI symbologies use the traditional
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 9.0 Data Analysis Screens After doing a scan, the Pass/Fail Analysis
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 27 Press Select to bring up the next screen: Ratio: 1.7 F This
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 The closer the “A” is to the edge, the more likely the Reject. A symbo
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 29 Table 9-A (LED, Bar code Width Deviations) 5 LED Display Pattern Ave
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 ISO/ANSI Analysis Screens Press Select again to display the first tech
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 31 Press Select to display the next screen: Defects 07% A Appl. Com
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 Press Select to bring up the next screen: Code 3of9 Acceptable
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 33 10.0 Connect to other Devices Connection to other Devices Connect to
Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix A (Symbology Analysis) Symbology Analysis Parameters Table A-1 shows error mess
Operator’s Guide Appendix A 002-5564 RJS, Minneapolis, MN 35 Table A-2 (Parameters Checked for Each Symbology) Symbology Ratio ICG Data Char
Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5564 Note 1: UPC/EAN tolerances: 80 - 89% = .14X 90 - 115% = .30X 116 - 150% = .34X 151
Operator’s Guide Appendix B 002-5564 RJS, Minneapolis, MN 37 Appendix B (ISO/ANSI Decodability) ISO/ANSI Decodability Calculations There is a sp
Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix C (Analysis Parameters) ISO/ANSI Parameter Grading
Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 39 RJS Inspector D4000 Analysis Parameters Edge Determination This parameter can be gr
Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 The parameter grade is determined by: 1. Calculating the edge contrast of every element
Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 41 Defects This parameter can be graded “A,” “B,” “C,” “D,” or “F.” Defects are irreg
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN i TABLE OF CONTENTS 1.0 PREFACE 1 1.1 PROPRIETARY STATEMENT 1 1.2 S
Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5564 If the Reference Decode parameter is “A,” then the overall symbol grade is determined by
Operator’s Guide Appendix C 002-5564 RJS, Minneapolis, MN 43 Traditional Analysis Tolerance Graph -100% Tol. +100% ------RRARR+++++ This graph
Appendix D Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix D (Quiet Zone Analysis) Quiet Zone Analysis The RJS Inspector D4000 trims data
Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 45 Appendix E (Code 128) Code 128 Code 128 can encode all the characters currently enco
Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Display of Code 128 The Inspector display can accommodate up to 16 characters. However,
Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 47 As indicated before, each of the 3 subsets have “unique” features: Subset A all
Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Character Set LCD Screen Table E-1 (Code 128 — Subset A) SP ! “ # $ % & ‘
Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 49 Character Set LCD Screen Table E-2 (Code 128 — Subset B) SP ! “ # $ % &
Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 Character Set LCD Screen Table E-3 (Code 128 — Subset C) 00 01 02 03 04 05 06 0
Operator’s Guide Appendix E 002-5564 RJS, Minneapolis, MN 51 90 91 92 92 94 95 96 97 98 99 9 9 9 9 9 9 9 9 9 9 0 1 2 3 4
Inspector D4000™ Auto Optic Operator’s Guide RJS, Minneapolis, MN 002-5564 TABLE 8-A (CODE IDENTIFIERS RJS INSPECTOR D4000) 24 TABLE 8-B (CODE I
Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5564 GS1-128 Symbology Specification When a Code 128 symbol is decoded AND the first characte
Operator’s Guide Appendix F 002-5564 RJS, Minneapolis, MN 53 Appendix F (Magnifications) UPC/EAN Magnifications & Bar Width Deviations UPC and
Appendix G Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix G (Aperture Selection) The D4000 Auto Optic has four different aperture (ligh
Operator’s Guide Appendix H 002-5564 RJS, Minneapolis, MN 55 Appendix H (Print Functions) Print Functions Scanned data may be printed if the RJS I
Appendix H Operator’s Guide RJS, Minneapolis, MN 002-5564 When printing the buffer in multiple scan mode, don’t initiate printing before all scans
Operator’s Guide Appendix I 002-5564 RJS, Minneapolis, MN 57 Appendix I (Computer Mode) Output Data When the Computer is enabled during Setup, as
Appendix I Operator’s Guide RJS, Minneapolis, MN 002-5564 Inspector D4000A Revision A.06 02-Scan Average Analysis C
Operator’s Guide Appendix J 002-5564 RJS, Minneapolis, MN 59 Appendix J (Battery Displays) Battery Displays If the “Low Battery” condition display
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Appendix K (Bar code definitions) Achieved Width The calculated element width based
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 61 Bar code A group of parallel bars and spaces constituting characters that ar
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN iii APPENDIX D (QUIET ZONE ANALYSIS) 44 QUIET ZONE ANALYSIS 44 TABLE
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Bit The narrowest code element (bar of space) that may contain information. Character T
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 63 Decode Determining the information which has been encoded in a bar code symbol. Deco
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Edge Contrast (EC) See Edge Contrast(min) The difference between the space reflec
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 65 Element Reflectance Non-uniformity (ERN) The reflectance difference between the highe
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The global threshold is drawn through the middle of a profile, to distinguish spaces abo
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 67 Inter-character Gap In discrete barcodes, the space that separates two adjacen
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The greatest reflectance value in a scan reflectance profile including quiet zone. (
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 69 The narrowest expected bar or space width. Moving Beam Scanner A laser device t
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The ability to read a bar code symbol from any angle as long as the bar code passes acro
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 71 Print Contrast Signal (PCS) A comparison between the reflectance (brightness dif
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 This parameter grade can be “A” or “F.” The reflec-tance value of the “lightest” space
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 73 A bar code or symbol that uses a checking algorithm that can be applied to each
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 The material (paper, plastic, metal, etc.) upon which a bar code symbol is “printed” or
Operator’s Guide Appendix K 002-5564 RJS, Minneapolis, MN 75 Technology Park/Atlanta, P.O. Box 105113 Atlanta, GA 30348-5115 Threshold (Global T
Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5564 Void White or light reflective area in a bar caused by a printing error that
Operator’s Guide Inspector D4000™ Auto Optic 002-5564 RJS, Minneapolis, MN 1 1.0 Preface 1.1 Proprietary Statement The RJS Inspector D4000 Operat
Komentarze do niniejszej Instrukcji